Generate/Update Block Symbols
The symbols for generating/updating hierarchy diagrams(Reuse Block) in schematic diagrams are mostly used to update blocks, top-down design hierarchy diagrams.
Top menu - Design - Generate update block symbol, click to generate a reuse block from the schematic or regenerate the changed content of the schematic.
Batch reuse
You can set batch reuse attributes in the right attributes of the reused module symbol instance to achieve the effect of batch reuse. For example, fill in the initial value in batch reuse as 1 and the end value as 10, then the instance reuses the module symbol. This is equivalent to reusing it 10 times.
Instance module symbols that are reused in batches can be switched to view different instances at the bottom of the canvas after right-clicking to expand them.
The pin attribute of the reused module symbol has the "Pin Multiplexing" attribute. When the user sets the pin to be reused, the pin name on the canvas will display the Reuse prefix. If it is set to a shared pin, only the pin name will be displayed.
When set to a shared pin, the port is fully connected between all instances.
When set as a multiplexed pin, the port is not connected between instances.
If a wire is connected to a multiplex pin, this wire is only connected to the first instance of the multiplexer.
If a multiplexed pin is connected to a bus, the bus branch is connected to the corresponding batch multiplexing instance (the connected batch multiplexing instance is determined according to the end of the branch number).